Preview

Devices and Methods of Measurements

Advanced search

Influence of the Level of Defective Insulation Resistance of Electrical Machine Windings on Parameters of no-Load Current

https://doi.org/10.21122/2220-9506-2024-15-4-307-315

Abstract

Diagnostic methods that will change at present for monitoring the condition of windings of electric machines do not allow to detect defect formation in them at early stages of development. And this problem is especially relevant for equipment that is directly in its operating mode. The purpose of the work was to consider and evaluate the possibility of a method that, based on the analysis of the parameters and characteristics of the no-load current, will allow to characterize the state of the current-carrying parts of the windings of diagnosed electric machines. The paper presents the results of experimental studies of the patterns of influence of the level of defective resistance of interturn insulation in the windings of electric machines on the parameters of the no-load current, including the features of changes in the parameters of its spectral components. The article also defines analytical dependencies of the obtained characteristics of influence and analyzes the factors that determine the measurement errors of the developed method. The presented method based on the analysis of the parameters of the spectral components of the no-load current is intended for measuring the resistance of the interturn insulation of current-carrying parts in the windings of electrical machines under their operating conditions, with the possibility of recording the onset of defect formation, which will allow real-time assessment of its operational, pre-failure and serviceable state.

About the Authors

A. V. Isaev
Belarusian National Technical University
Belarus

Address for correspondence:
Isaev A.V.–
Belarusian National Technical University,
Nezavisimosty Ave., 65, Minsk 220013, Belarus
e-mail: isaevav@bntu.by




Yu. V. Suhodolov
Belarusian National Technical University
Belarus

Nezavisimosty Ave., 65, Minsk 220013



S. V. Sizikov
Belarusian National Technical University
Belarus

Nezavisimosty Ave., 65, Minsk 220013



A. A. Lomtev
Belarusian National Technical University
Belarus

Nezavisimosty Ave., 65, Minsk 220013



V. A. Lychkovsky
Belarusian National Technical University
Belarus

Nezavisimosty Ave., 65, Minsk 220013



References

1. Dudkin AN, Matyalis AP, Muravlev OP. Ensuring the quality and reliability of electrical machines. Bulletin of Tomsk Polytechnic University, 2000; 303(1):266-269.

2. Review JL, Pavel T. Failures of Electrical Machines. Department of Materials and Technology, Faculty of Electrical Engineering University of West Bohemia Pilsen, Czech republic 2022 8th International Youth Conference on Energy (IYCE).

3. Izmereniye soprotivleniya izolyatsii: rukovodstvo [Insulation resistance measurement: manual] [Electronic resource]. 1997–2024 "SvyazKomplekt" (OOO "KatalogService", OGRN: 1097746354474) – Access mode: https://skomplekt.com/izmerenie-soprotivleniia-izoliatcii/

4. Adam Decner, Marcin Baranski, Tomasz Jarek, Sebastian Berhausen Methods of Diagnosing the Insulation of Electric Machines Windings Energies. 2022;15(8465).

5. “A Stitch In Time” The Complete Guide to Electrical Insulation Testing, 2006. [Electronic resource]. Access mode: https://www.instrumart.com/assets/Megger-Guide-to-Insulation-Testing.pdf

6. Gruntovich NV, Grachek NI. Comprehensive technical diagnostics of electrical equipment – the basis of the “condition-based” repair system. Mining journal. 2003;(7):67-69.(In Russ.).

7. Ismagilov FR [et al.]. Review of modern methods and means of operational diagnostics of electromechanical energy converters. Ufa: Bulletin of Ufa State Agrarian University, 2010;14;4(39):73-79. (In Russ.).

8. ISO 13379 (all parts). Condition monitoring and diagnostics of machines – Data interpretation and diagnostics techniques. 2012. 33 p.

9. Noveyshiye sistemy diagnostiki sostoyaniya elektrodvigateley [The latest systems for diagnosing the condition of electric motors] [Electronic resource]. – Electronic data. – M., [2011]. – Access mode: http://kart.od.ua/Sistema_diagnostiki.html.

10. Izmereniye soprotivleniya izolyatsii elektrooborudovaniya: normy i rekomendatsii [Measurement of insulation resistance of electrical equipment: standards and recommendations] [Electronic resource]. 2011. Electronic data. Access mode: https://test-energy.ru/soprotivlenie-izolyacii-ehlektrooborudovaniya-normy-i-rekomendacii-po-izmereniyu/

11. Cruz S.M.A, Cardoso A.J.M. Stator winding fault diagnosis in threephase synchronous and asynchronous motors by the extended Park's vector approach. IEEE Trans. Ind. A. 2001;37:1227-1233.

12. Cardoso A.J.M, Saraiva ES. Computer-aided detection of airgap eccentricity in operating threephase induction motors by Paris's vector approach. IEEE Trans. Ind. A. 1993;29:897-901.

13. Isaev AV. [et al.]. Determination of defects in windings of electrical machines by parameters of the noload current spectrum. Metrology and instrument making. 2022;1:17-23. (In Russ.).


Review

For citations:


Isaev A.V., Suhodolov Yu.V., Sizikov S.V., Lomtev A.A., Lychkovsky V.A. Influence of the Level of Defective Insulation Resistance of Electrical Machine Windings on Parameters of no-Load Current. Devices and Methods of Measurements. 2024;15(4):307-315. (In Russ.) https://doi.org/10.21122/2220-9506-2024-15-4-307-315

Views: 324


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2220-9506 (Print)
ISSN 2414-0473 (Online)