APPARATUS REALIZATION AND APPROVAL OF NON-INVASIVE DIAGNOSTICS OF HEMODYNAMICS BASED ON TENSOMETRY AND EXTЕNDED TONOMETRY
Abstract
The results of development of special program and apparatus unit «SPAS» for biomechanical diagnostics of cardiovascular system by oscillometry method have been presented. The estimation of possibilities of apparatus realization based on tensometric station TS-32 is been given.
About the Authors
S. V. Shil’koBelarus
Yu. G. Kuzminsky
Belarus
M. V. Borisenko
Belarus
References
1. . Skinner S.L. SphygmoCor Clinical Guide. [At the Heart of Cardivascular Management], 2001, p. 78: Available at: www.artcormedical.com.: accessed 02.02.2013.
2. Degtyarev V.A. [Possibility of a comprehensive study of the circulatory system of the population by volumetric compression oscillometry]. Rossijskie meditsinskie vesti, 2003, no. 4, pp. 18–28 (in Russian).
3. Ivanov S.Yu., Livshits N.I. [The accuracy of blood pressure measurement on Korotkov’s tones compared with oscillometric method]. Vestnik aritmologii, 2005, no. 40, pp. 55–58 (in Russian).
4. Tsupko I.V. Sposob opredeleniya arterial’nogo davleniya, parametrov gemodinamiki i sostoyaniya sosudistoj stenki s ispol’zovaniem ostsilometrii vysokogo razresheniya [A method for determination of blood pressure, hemodynamic parameters and the condition of the vascular wall using high resolution oscillometry]. Patent RF, no. 2360596, 2006.
5. Parashin V.B., Simonenko M.N. [Technical and metrological aspects of blood pressure measurement by the oscillometric method]. Meditsinskaya tekhnika, 2010, no. 1, pp. 22–26 (in Russian). 6. Babbs C.F. Oscillometric Measurement of Systolic and Diastolic Blood Pressures Validated in a Physiologic Mathematical Model. BioMedical Engineering OnLine. Available at: http://www.biomedical-engineeringonline.com/content/11/1/56 (accessed 23.09.2014).
6. Gallagher A.J. Blood Gas, Oxygen Saturation, pH, and Lactate Values in Elasmobranch Blood Measured with a Commercially Available Portable Clinical Analyzer and Standard Laboratory Instruments // J. of Aquatic Animal Health, 2010, vol. 22, pp. 229–234.
7. Parfenov A.S. [Early diagnosis of cardiovascular disease with the use of hardware-software complex «Angioscan-01»]. Poliklinika, 2012, no. 2/1, pp. 70–74 (in Russian).
8. Shil’ko S.V., Shevtsov V.V. [Hardware and software system for monitoring the cardiovascular system based on tonometry]. Pribory i metody izmerenij, 2012, no. 2(3), pp. 53–60 (in Russian).
9. Shevtsov V.V., Shil’ko S.V., Borisenko M.B., Kuzminsky Yu.G. [Hardware implementation of biomechanical diagnosis of cardiovascular system according to the oscillometry]. Pribory i metody izmerenij, 2012, no. 2(5), pp. 51–55 (in Russian).
10. Shil’ko S.V., Kuzminsky Yu.G., Borisenko M.B. [Маthematical model and program realization of heart and vessel system monitoring]. Problemy fisiki, matematiki i tekhniki, 2011, no. 3, pp. 104–112 (in Russian).
11. Shil’ko S.V., Kuzminsky Yu.G., Shevtsov V.V. Svidetel'stvo o registratsii programmnogo produkta SPAS V1.0 dlia biomekhanicheskoj diagnostiki i monitoringa serdechno-sosudistoj sistemy [Certificate on the registration software SPAS V1.0 for biomechanical diagnosis and monitoring of cardiovascular system]. Certificate RB, no. 456, 2012.
12. Kuzminsky Yu.G., Shil’ko S.V. Svidetel'stvo o registratsii komp'yuternoj programmy BIODIS V2.5 [Certificate of registration of a computer program BIODIS V2.5]. Certificate RB, no. 455, 2012.
Review
For citations:
Shil’ko S.V., Kuzminsky Yu.G., Borisenko M.V. APPARATUS REALIZATION AND APPROVAL OF NON-INVASIVE DIAGNOSTICS OF HEMODYNAMICS BASED ON TENSOMETRY AND EXTЕNDED TONOMETRY. Devices and Methods of Measurements. 2015;6(1):39-46. (In Russ.)