<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">pimi</journal-id><journal-title-group><journal-title xml:lang="ru">Приборы и методы измерений</journal-title><trans-title-group xml:lang="en"><trans-title>Devices and Methods of Measurements</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2220-9506</issn><issn pub-type="epub">2414-0473</issn><publisher><publisher-name>BNTU</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21122/2220-9506-2017-8-1-23-31</article-id><article-id custom-type="elpub" pub-id-type="custom">pimi-284</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Средства измерений</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Measuring instruments</subject></subj-group></article-categories><title-group><article-title>ВЛИЯНИЕ РАССЕЯННОГО НЕЙТРОННОГО ИЗЛУЧЕНИЯ НА МЕТРОЛОГИЧЕСКИЕ ХАРАКТЕРИСТИКИ ПОВЕРОЧНОЙ УСТАНОВКИ НЕЙТРОННОГО ИЗЛУЧЕНИЯ УПН-АТ140</article-title><trans-title-group xml:lang="en"><trans-title>INFLUENCE OF SCATTERED NEUTRON RADIATION ON METROLOGICAL CHARACTERISTICS OF АТ140 NEUTRON CALIBRATION FACILITY</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Комар</surname><given-names>Д. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Komar</surname><given-names>D. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Адрес для переписки: Комар Д.И. – НПУП «АТОМТЕХ», ул. Гикало, 5, г. Минск 220005, Беларусь    e-mail: damiankomar@yandex.ru</p></bio><bio xml:lang="en"><p>Address for correspondence: Komar D. – SPE «АТОМТЕХ», Gikalo str. 5 , Minsk 220005, Belarus    e-mail: damiankomar@yandex.ru</p></bio><email xlink:type="simple">damiankomar@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кутень</surname><given-names>С. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Kutsen</surname><given-names>S. A.</given-names></name></name-alternatives><bio xml:lang="en"><p>Institute of Nuclear Problems</p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>АТОМТЕХ</institution><country>Беларусь</country></aff><aff xml:lang="en"><institution>АТОМТЕХ</institution><country>Belarus</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Институт ядерных проблем Белорусского государственного университета</institution><country>Беларусь</country></aff><aff xml:lang="en"><institution>Belarusian State University</institution><country>Belarus</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2017</year></pub-date><pub-date pub-type="epub"><day>28</day><month>02</month><year>2017</year></pub-date><volume>8</volume><issue>1</issue><fpage>23</fpage><lpage>31</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Комар Д.И., Кутень С.А., 2017</copyright-statement><copyright-year>2017</copyright-year><copyright-holder xml:lang="ru">Комар Д.И., Кутень С.А.</copyright-holder><copyright-holder xml:lang="en">Komar D.I., Kutsen S.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://pimi.bntu.by/jour/article/view/284">https://pimi.bntu.by/jour/article/view/284</self-uri><abstract><p>В метрологическом обеспечении средств измерений нейтронного излучения в качестве эталонов широкое распространение получили установки с коллимированным полем излучения, создаваемым радионуклидными источниками нейтронов. Целью данной работы являлось исследование влияния рассеянного нейтронного излучения на такие метрологические характеристики поверочной установки нейтронного излучения УПН-АТ140, как плотность потока и амбиентный эквивалент мощности дозы с использованием метода Монте-Карло.</p><p>При калибровке испытуемый прибор помещают в нейтронное поле с известной плотностью потока или амбиентным эквивалентом мощности дозы. Пучок нейтронов от радионуклидного источника быстрых нейтронов может быть сформирован в различных геометриях. В контейнере-коллиматоре установки поверочной нейтронного излучения УПН-АТ140 устанавливаются специальные вставки, отвечающие геометрии быстрых и геометрии тепловых нейтронов. Из-за наличия рассеянного излучения необходимо вносить поправки на рассеянную компоненту, обусловленную рассеянием нейтронов в воздухе и стенами помещения. Измерение характеристик нейтронного поля установки могут быть проведены в ограниченном числе точек, а в остальных точках используется модельный метод.</p><p>Контейнер-коллиматор установки со вставкой для геометрии тепловых нейтронов формирует пучок от радионуклидного источника нейтронов со значительной составляющей нейтронов тепловых энергий. Из полученной зависимости полного потока нейтронов от расстояния до источника нейтронов видно, что за счет рассеянного в коллиматоре излучения нарушается закон обратных квадратов. Вклад рассеянного стенами помещения излучения в полный поток нейтронов увеличивается при удалении от источника нейтронов и значительно влияет на характеристики поля нейтронов. При открытом источнике в геометрии теневого конуса, спектр нейтронов имеет ярко выраженную тепловую компоненту, обусловленную рассеянием от стен.</p><p>Рассмотрены основные типы геометрий для формирования поля эталонного нейтронного излучения с использованием радионуклидных источников. Разработана Монте-Карло модель 238Pu-Be-источника нейтронов и контейнера-коллиматора установки УПН-АТ140. Показано, что наиболее существенным фактором, влияющим на энергетическое распределение нейтронов, является вклад излучения, рассеянного в помещении, где расположена установка. Это приводит к значительному изменению спектра нейтронного излучения при удалении от источника. При проектировании помещения и размещения в нем установки необходимо учитывать требования к качеству излучения. </p></abstract><trans-abstract xml:lang="en"><p>Today facilities with collimated radiation field are widely used as reference in metrological support of devices for neutron radiation measurement. Neutron fields formed by radionuclide neutron sources. The aim of this research was to study characteristics of experimentally realized neutron fields geometries on АТ140 Neutron Calibration Facility using Monte Carlo method.</p><p>For calibration, we put a device into neutron field with known flux density or ambient equivalent dose rate. We can form neutron beam from radionuclide fast-neutron source in different geometries. In containercollimator of АТ140 Neutron Calibration Facility we can install special inserts to gather fast-neutron geometry or thermal-neutron geometry. We need to consider neutron scattering from air and room’s walls. We can conduct measurements of neutron field characteristics in several points and get the other using Monte Carlo method.</p><p>Thermal neutron collimator forms a beam from radionuclide source with a significant amount of neutrons with thermal energies. From found relationship between full neutron flux and distance to neutron source we see that inverse square law is violated. Scattered radiation contribution into total flux increases when we are moving away from neutron source and significantly influences neutron fields characteristics. While source is exposed in shadow-cone geometry neutron specter has pronounced thermal component from wall scattering.</p><p>In this work, we examined main geometry types used to acquire reference neutron radiation using radionuclide sources. We developed Monte Carlo model for 238Pu-Be neutron source and АТ140 Neutron Calibration Facility’s container-collimator. We have shown the most significant neutron energy distribution factor to be scattered radiation from room’s walls. It leads to significant changes of neutron radiation specter at a distance from the source. When planning location, and installing the facility we should consider radiation quality requirements. </p></trans-abstract><kwd-group xml:lang="ru"><kwd>Монте-Карло моделирование</kwd><kwd>радионуклидный источник нейтронов</kwd><kwd>поле нейтронного излучения</kwd><kwd>коллиматор</kwd><kwd>метод теневого конуса</kwd></kwd-group><kwd-group xml:lang="en"><kwd>Monte Carlo simulation</kwd><kwd>radionuclide neutron source</kwd><kwd>fields of neutron radiation</kwd><kwd>collimator</kwd><kwd>shadow cone method</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Eisenhauer, C.M. Calibration Techniques for Neutron Personal Dosymetry / C.M. Eisenhauer, J.B. Hunt, R.B. Schwartz // Radiation Protection Dosimetry. – 1985. – Vol. 10, iss. 1–4. – P. 43–57.</mixed-citation><mixed-citation xml:lang="en">Eisenhauer C.M., Hunt J.B., Schwartz R.B. Calibration Techniques for Neutron Personal Dosymetry. Radiation Protection Dosimetry, 1985, vol. 10, iss. 1–4, pp. 138–147. doi: 10.1093/oxfordjournals.rpd.a079410</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Vega-Carrillo, H.R. Spectrometry and dosimetry of a neutron source / H.R. Vega-Carillo, E. ManzanaresAcuna, V.M. Hernandez-Davila // Radiation Effects and Defects in Solids. – 2009. – Vol. 164, iss. 4. – P. 218–223.</mixed-citation><mixed-citation xml:lang="en">Vega-Carillo H. R., Manzanares-Acuna E., Hernandez-Davila V. M. Spectrometry and dosimetry of a neutron source. Radiation Effects and Defects in Solids, 2009, vol. 164, iss. 4, pp. 218-223. doi: 10.1080/10420150802271522</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Vega-Carillo, H.R. Study of room-return neutrons. / H.R. Vega-Carillo, E. Manzanares-Acuna, M.P. Iniguez. // Radiation Measurements. – 2007. – Vol. 42, iss. 3. – P. 413–419.</mixed-citation><mixed-citation xml:lang="en">Vega-Carillo H.R., Manzanares-Acuna E., Iniguez M.P. Study of room-return neutrons. Radiation Measurements, 2007, vol. 42, iss. 3, pp. 413–419. doi: 10.1016/j.radmeas.2007.01.036</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">McCall, R.C. Room scattered neutrons / R.C. McCall, P.H. McGinley, K.E. Huffman // Medical Physics. – 1999. – Vol. 26, iss. 2. – P. 205–207.</mixed-citation><mixed-citation xml:lang="en">McCall R.C., McGinley P.H., Huffman K.E. Room scattered neutrons. Medical Physics, 1999, vol. 26, iss. 2, pp. 205–207. doi: 10.1118/1.598505</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Gallego, E. Characterictics of the Neutron Field of the Facility at DIN-UPM / E. Gallego, A. Lorente // Radiation Protection Dosimetry. – 2004. – Vol. 110, iss. 1–4. – P. 73–79.</mixed-citation><mixed-citation xml:lang="en">Gallego E., Lorente A. Characterictics of the Neutron Field of the Facility at DIN-UPM. Radiation Protection Dosimetry, 2004, vol. 110, iss. 1–4, pp. 73– 79. doi: 10.1093/rpd/nch199</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Eisenhauer, C.M. Effect of Air Scatter on Calibration of Instruments for Detecting Neutrons / C.M. Eisenhauer, R.B. Schwartz, R.C. McCall // Radiation Protection Dosimetry. – 1987. – Vol. 19, iss. 2. – P. 77–84.</mixed-citation><mixed-citation xml:lang="en">Eisenhauer C.M., Schwartz R.B., McCall R.C. Effect of Air Scatter on Calibration of Instruments for Detecting Neutrons. Radiation Protection Dosimetry, 1987, vol. 19, iss. 2, pp. 77–84. doi: 10.1093/oxfordjournals.rpd.a079923</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Hunt, J.B. The Сalibration of Neutron Sensetive Spherical Devices / J.B. Hunt // Radiation Protection Dosimetry. – 1984. – Vol. 8, iss. 4. – P. 239–251.</mixed-citation><mixed-citation xml:lang="en">Hunt J.B. The Сalibration of Neutron Sensetive Spherical Devices. Radiation Protection Dosimetry, 1984, vol. 8, iss. 4, pp. 239–251. doi: 10.1093/oxfordjournals.rpd.a083078</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Briesmeister, J.F. MCNP-A General Monte Carlo N-Paticle Transport Code, Version 4В. LA-12625-M./ J.F. Briesmeister; ed. Los Alamos National Laboratory. – Los Alamos, 1997, 736 с.</mixed-citation><mixed-citation xml:lang="en">Briestmeister J.F. ed. MCNP-A general Monte Carlo N-particle transport code, Version 4A. Report LA-12625-M, Los Alamos, NM: Los Alamos National Laboratory,1994, 736 pp.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Kim, S.I. Review of neutron scattering correction for the calibration of neutron survey meters using the shadow-cone metod / S.I. Kim, B.H. Kim, J.L. Kim // Nuclear Engineering and Technology. – 2015. – Vol. 47, iss. 7. – P. 939–944.</mixed-citation><mixed-citation xml:lang="en">Kim S.I., Kim B.H., Kim J.L. Review of neutron scattering correction for the calibration of neutron survey meters using the shadow-cone metod. Nuclear Engineering and Technology, 2015, vol. 47, iss. 7, pp. 939–944. doi: 10.1016/j.net.2015.07.005</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Eisenhauer, C.M. Review of Scattering Corrections for Calibration of Neutron Instruments / C.M. Eisenhauer // Radiation Protection Dosimetry. – 1989. – Vol. 28, iss. 4. – P. 253–262.</mixed-citation><mixed-citation xml:lang="en">Eisenhauer C.M. Review of Scattering Corrections for Calibration of Neutron Instruments. Radiation Protection Dosimetry, 1989, vol. 28, iss. 4, pp. 253–262. doi: 10.1093/oxfordjournals.rpd.a080514</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Vega-Carillo, H.R. Low energy neutrons from a 239PuBe isotopic neutron source inserted in moderating media / H.R. Vega-Carillo, C.T. Muhech // Revista Mexicana de Fisica. – 2002. – Vol. 48, iss. 5. – P. 405–412.</mixed-citation><mixed-citation xml:lang="en">Vega-Carillo H.R., Muhech C.T. Low energy neutrons from a 239PuBe isotopic neutron source inserted in moderating media. Revista Mexicana de Fisica, 2002, vol. 48, iss. 5, pp. 405–412.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Faghihi, F. Neutrons Flux Distributions of the Pu-Be Source and its Simulation by the MCNP-4B Code / F. Faghihi, S. Mehdizadeh, K. Hadad // International Journal of Modern Physics. – 2006. – Vol. 15, iss. 3. – P. 737–745.</mixed-citation><mixed-citation xml:lang="en">Faghihi F., Mehdizadeh S., Hadad K. Neutrons Flux Distributions of the Pu-Be Source and its Simulation by the MCNP-4B Code. International Journal of Modern Physics, 2006, vol. 15, iss. 3, pp. 737–745. doi: 10.1142/S0218301306004545.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
