<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">pimi</journal-id><journal-title-group><journal-title xml:lang="ru">Приборы и методы измерений</journal-title><trans-title-group xml:lang="en"><trans-title>Devices and Methods of Measurements</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2220-9506</issn><issn pub-type="epub">2414-0473</issn><publisher><publisher-name>BNTU</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">pimi-24</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Методы измерений, контроля, диагностики</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Methods of measurements, monitoring, diagnostics</subject></subj-group></article-categories><title-group><article-title>МЕТОДИКА И АППАРАТНЫЕ СРЕДСТВА ВЕРИФИКАЦИИ ОТПУСКА ДОЗЫ ПРИ ДИНАМИЧЕСКИХ МЕТОДАХ ДИСТАНЦИОННОЙ ЛУЧЕВОЙ ТЕРАПИИ</article-title><trans-title-group xml:lang="en"><trans-title>METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Титович</surname><given-names>Е. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Tsitovich</surname><given-names>Y. V.</given-names></name></name-alternatives><email xlink:type="simple">e.v.titovich@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Гмырак</surname><given-names>А. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Hmyrak</surname><given-names>A. I.</given-names></name></name-alternatives><email xlink:type="simple">e.v.titovich@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Тарутин</surname><given-names>И. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Tarutin</surname><given-names>A. I.</given-names></name></name-alternatives><email xlink:type="simple">e.v.titovich@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Киселев</surname><given-names>М. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Kiselev</surname><given-names>M. G.</given-names></name></name-alternatives><email xlink:type="simple">e.v.titovich@gmail.com</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>РНПЦ онкологии и медицинской радиологии им. Н.Н. Александрова,&#13;
г. Минск</institution><country>Belarus</country></aff><aff xml:lang="ru" id="aff-2"><institution>Белорусский национальный технический университет</institution><country>Belarus</country></aff><pub-date pub-type="collection"><year>2013</year></pub-date><pub-date pub-type="epub"><day>30</day><month>03</month><year>2015</year></pub-date><volume>0</volume><issue>1</issue><fpage>97</fpage><lpage>102</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Титович Е.В., Гмырак А.И., Тарутин И.Г., Киселев М.Г., 2015</copyright-statement><copyright-year>2015</copyright-year><copyright-holder xml:lang="ru">Титович Е.В., Гмырак А.И., Тарутин И.Г., Киселев М.Г.</copyright-holder><copyright-holder xml:lang="en">Tsitovich Y.V., Hmyrak A.I., Tarutin A.I., Kiselev M.G.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://pimi.bntu.by/jour/article/view/24">https://pimi.bntu.by/jour/article/view/24</self-uri><abstract><p>Приведено описание оригинальной конструкции фантома для проведения верификации планов облучения при использовании динамических методов дистанционной лучевой терапии, позволившего разработать методику проведения кросс-калибровки комплексных дозовых распределений, основанной на однократном измерении стабильных во времени значений калибровочных коэффициентов,  что обеспечивает необходимую  реализацию запланированного распределения поглощённой дозы, сокращает продолжительность подготовки к проведению сеансов облучения пациентов и увеличивает пропускную способность ускорителя</p></abstract><trans-abstract xml:lang="en"><p>The design of special verification phantom for dynamic radiotherapy checking is described. This phantom permits to insert the dose distribution cross-calibration before every days patients irradiation on Linac with RapidArc. Cross-calibration factor is defined by approximation of large number correction factors measured in phantom at different angles of gantry rotation and middle quantity calculation. The long range stability of all correction factors have been evaluated during checking of setting treatment plans and did not exceed 1 %. The fast checking of patient’s dynamic irradiation with developed method gives possibility texactly realize of planning dose distribution and to increase the capacity of accelerators.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>лучевая терапия</kwd><kwd>объемная модуляция интенсивности дозы</kwd><kwd>верификация отпуска дозы</kwd><kwd>кросс-калибровка комплексных дозовых распределений</kwd><kwd>конструкция верификационного фантома</kwd></kwd-group><kwd-group xml:lang="en"><kwd>RapidArc</kwd><kwd>dose output verification</kwd><kwd>cross-calibration of complex dose fluences</kwd><kwd>verification phantom construction</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">IMRT commissioning: Multiple institution planning and Dosimetry comparisons / Report AAPM Task Group 119. – 2009.</mixed-citation><mixed-citation xml:lang="en">IMRT commissioning: Multiple institution planning and Dosimetry comparisons / Report AAPM Task Group 119. – 2009.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Jørgensen Mai-Britt K. Machine-specific QC in Aarhus using EPID / K. Mai-Britt Jørgensen, L. Hoffmann, L.P. Muren [et al.] / Proceed of RA workshop // Denmark 2012.</mixed-citation><mixed-citation xml:lang="en">Jørgensen Mai-Britt K. Machine-specific QC in Aarhus using EPID / K. Mai-Britt Jørgensen, L. Hoffmann, L.P. Muren [et al.] / Proceed of RA workshop // Denmark 2012.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Hoffmann, L. Patient specific QC in Aarhus / L. Hoffmann, U.V. Elstrøm, K. Mai-Britt Jørgensen / Proceed of RA workshop // Denmark 2012.</mixed-citation><mixed-citation xml:lang="en">Hoffmann, L. Patient specific QC in Aarhus / L. Hoffmann, U.V. Elstrøm, K. Mai-Britt Jørgensen / Proceed of RA workshop // Denmark 2012.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Fredh, A. RapidArc QA at Rigshospitalet / A. Fredh, M. Hörling // Proceed of RA workshop // Denmark 2012.</mixed-citation><mixed-citation xml:lang="en">Fredh, A. RapidArc QA at Rigshospitalet / A. Fredh, M. Hörling // Proceed of RA workshop // Denmark 2012.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Nicolini, G. GLAaS: An absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications / G. Nicolini, A. Fogliata, E. Vanetti [et al.] // Med. Phys. – V. 33. – 2006. – P. 2839.</mixed-citation><mixed-citation xml:lang="en">Nicolini, G. GLAaS: An absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications / G. Nicolini, A. Fogliata, E. Vanetti [et al.] // Med. Phys. – V. 33. – 2006. – P. 2839.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Nicolini, G. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy / G. Nicolini, E. Vanetti, A. Clivio [et al.] // Radiation Oncology. – V. 3. – 2008. – P. 24–32.</mixed-citation><mixed-citation xml:lang="en">Nicolini, G. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy / G. Nicolini, E. Vanetti, A. Clivio [et al.] // Radiation Oncology. – V. 3. – 2008. – P. 24–32.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Essers, M. Commissioning of a commercially available system for intensitymodulated radiotherapy dose delivery with dynamic multileaf collimation / M. Essers, M. De Langen, M.L.P. Dirkx [et al.] // Radiotherapy and Oncology. – V. 60. – 2001. – P. 215–224.</mixed-citation><mixed-citation xml:lang="en">Essers, M. Commissioning of a commercially available system for intensitymodulated radiotherapy dose delivery with dynamic multileaf collimation / M. Essers, M. De Langen, M.L.P. Dirkx [et al.] // Radiotherapy and Oncology. – V. 60. – 2001. – P. 215–224.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Absorbed dose determination in external beam radiotherapy / An international Code of Practice for Dosimetry Based on Standards of Absorbed dose to Water // IAEA. Technical Report Series. – № 398. – Vienna, 2000.</mixed-citation><mixed-citation xml:lang="en">Absorbed dose determination in external beam radiotherapy / An international Code of Practice for Dosimetry Based on Standards of Absorbed dose to Water // IAEA. Technical Report Series. – № 398. – Vienna, 2000.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Bocanek, J. Report from the feasibility testing of MatriXX device for RapidArc QA / J. Bocanek // Proceed of Varian Medical Systems workshop. – 2008.</mixed-citation><mixed-citation xml:lang="en">Bocanek, J. Report from the feasibility testing of MatriXX device for RapidArc QA / J. Bocanek // Proceed of Varian Medical Systems workshop. – 2008.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Van Esch, A. Dominique P. Huyskens Mauro Iori Christian Clermont and Magali Devillers On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom / A. Van Esch, D.P. Huyskens, M. Iori // Med. Phys. – V. 34. – 2007. – P. 3825–3837.</mixed-citation><mixed-citation xml:lang="en">Van Esch, A. Dominique P. Huyskens Mauro Iori Christian Clermont and Magali Devillers On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom / A. Van Esch, D.P. Huyskens, M. Iori // Med. Phys. – V. 34. – 2007. – P. 3825–3837.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Depuydt, T. A quantitative evaluation of IMRT dose distributions: refinement and clinical a ssessment of the gamma evaluation / T. Depuydt A. Van Esch, D.P. Huyskens // Radiotherapy and Oncology. – V. 62. – 2002. – P. 309–319.</mixed-citation><mixed-citation xml:lang="en">Depuydt, T. A quantitative evaluation of IMRT dose distributions: refinement and clinical a ssessment of the gamma evaluation / T. Depuydt A. Van Esch, D.P. Huyskens // Radiotherapy and Oncology. – V. 62. – 2002. – P. 309–319.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Van Esch, A. Acceptance tests and quality control (QC) procedures for the clinical i mplementation of intensity modulated radiothe rapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments / A. Van Esch, J. Bohsungb, P. Sorvaric [et al.] // Radiotherapy and Oncology. – V. 65. – 2002. – P. 53–70.</mixed-citation><mixed-citation xml:lang="en">Van Esch, A. Acceptance tests and quality control (QC) procedures for the clinical i mplementation of intensity modulated radiothe rapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments / A. Van Esch, J. Bohsungb, P. Sorvaric [et al.] // Radiotherapy and Oncology. – V. 65. – 2002. – P. 53–70.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
